Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 56
Filter
Add filters








Year range
1.
Chinese Journal of Ultrasonography ; (12): 338-344, 2022.
Article in Chinese | WPRIM | ID: wpr-932409

ABSTRACT

Objective:To evaluate the ability of vascular endothelial growth factor receptor 2(VEGFR2)/integrin α vβ 3 dual-targeted microubble (MBD) to target angiogenesis of renal cell carcinoma (RCC) in vivo. Methods:Non-targeted microbubble (MBN) USphere LA was employed as a template to prepare single- and dual-targeted microbubbles which could bind VEGFR2 and/or integrin α vβ 3 (MBV and MBI) by the biotin-avidin bridging method. A total of 40 RCC nude mice models were established by subcutaneously injecting 786-O cells.Twenty of the models were all injected with MBN, MBV, MBI and MBD in a random order, and the other 20 models were registered for antibody blocking assays. The results of ultrasound images were used for quantitative analyses, and the following quantitative parameters were obtained: intensity increment (a 1), peak halving speed (a 2), curve rising slope (a 3), perfusion time (t 0), time to peak (TTP), peak intensity (PI), mean transit time (MTT) and area under the curve (AUC) for the first three minutes, peak intensity at 10 s before (P 1) and after (P 2) ultrasound destruction, and the differences of tissue enhancement (dTE) between P 1 and P 2 (dTE=P 1-P 2). All the quantitative parameters of four contrast agents and the antibody blocking assays were compared.Besides, the immunohistochemical assays were performed to evaluate the expression of CD31, VEGFR2 and integrin α vβ 3 in tumor tissues. Results:The differences of parameters of a 1, a 3, t 0, TTP, PI and P 2 among four different microbubbles had no statistical significances (all P>0.05), and all parameters between the two single-targeted contrast agents were not statistically different (all P>0.05). The parameters of AUC, MTT, P 1 and dTE all showed a trend that dual-targeted bubbles > single-targeted bubbles > non-targeted bubbles (all P<0.05). On the contrary, the trend of dual-targeted bubbles < single-targeted bubbles < non-targeted bubbles (all P<0.05) was observed for a 2. In the antibody blocking experiment, a 2 was faster after the antibody injection ( P<0.001), while AUC, MTT, P 1 and dTE were all lower than those before the antibody injection ( P<0.001), and the other parameters were not statistically different before and after the antibody injection (all P>0.05). Immunohistochemical analyses confirmed the high expression of CD31, VEGFR2 and integrin β 3 in tumor tissues. Conclusions:The VEGFR2 and integrin α vβ 3 dual-targeted microbubble has a good potential to target the angiogenesis of human RCC in vivo.

2.
Chinese Journal of Ultrasonography ; (12): 1077-1083, 2022.
Article in Chinese | WPRIM | ID: wpr-992798

ABSTRACT

Objective:To explore the capability of vascular endothelial growth factor receptor 2 (VEGFR2)/integrinα vβ 3 dual-targeted microbubbles in assessing the expression level of pro-angiogenic factors during renal cell carcinoma (RCC) growth. Methods:VEGFR2/integrinα vβ 3 dual-targeted microbubbles were prepared by using biotin-avidin linkage method. Twenty subcutaneous RCC xenografts in nude mice were established by subcutaneously injecting 786-O cells and then divided into 2 groups randomly. The targeted contrast-enhanced ultrasound (t-CEUS) examination was performed for all 10 mice in the first group when xenograft tumors were metered from 5 to 10 mm and >10 to 20 mm respectively. And the quantitative parameters of RCC on t-CEUS were longitudinally evaluated during tumor growth. The second group were divided into two subgroups according to xenograft tumors′ diameter, which was 5 to 10 mm and >10 to 20 mm respectively, and underwent t-CEUS examination. Quantitative analysis was performed for all t-CEUS images to obtain the targeted quantitative parameters, which including peak intensity (PI), area under the time-intensity curve (AUC), the differential tissue enhancement (dTE, presenting the difference in PI before (P 1) and after (P 2) the process of Flash). All xenograft tumors in the second group were harvested for immunohistochemical staining to observe the expression of VEGFR2, integrinα vβ 3 and CD31, and their differences in RCC with different tumor sizes. And the correlations between quantitative parameters and VEGFR2, integrinα vβ 3 and CD31 were analyzed. Results:The longitudinal comparison showed that there were statistically significant differences between AUC and dTE of RCC with different tumor sizes (all P<0.001). The larger the tumor size, the smaller the parameters were. According to the horizontal comparison, the expression levels of VEGFR2 and integrinα vβ 3 in larger RCCs were higher than those of RCCs with smaller size (both P<0.05), but there was no significant difference in CD31 expression between the two subgroups ( P=0.754). Both the targeted quantitative parameters (AUC anddTE ) and pro-angiogenic factors (VEGFR2 and integrinα vβ 3) were negatively correlated with tumor size ( rs=-0.83, -0.81, -0.70, -0.88; all P<0.05). Further more, there were good positive correlations between AUC and VEGFR2, integrinαvβ ( rs=0.76, 0.72; all P<0.05). There were good positive correlations between dTE and VEGFR2, integrinα vβ 3 ( rs=0.81, 0.70; all P<0.05). Additionally, the parameter PI was positively correlated with the expression of CD31 ( rs=0.70, P=0.025). Conclusions:The t-CEUS, mediated by VEGFR/integrinα vβ 3 dual-targeted microbubbles, allows noninvasive assessment of the expression levels of VEGFR2 and integrinα vβ 3 in RCCs, which decrease gradually with the increase of tumor size.

3.
Chinese Journal of Ultrasonography ; (12): 868-873, 2021.
Article in Chinese | WPRIM | ID: wpr-910132

ABSTRACT

Objective:To explore the diagnostic performance of ultrasound attenuation imaging (ATI) in grading the degree of hepatic steatosis in metabolic dysfunction-associated fatty liver disease (MAFLD).Methods:The liver gray-scale ultrasound and ATI examinations were performed on 212 subjects who were treated in Zhongshan Hospital Affiliated to Fudan University from August 2020 to March 2021. The attenuation coefficient(AC) values among different degrees of hepatic steatosis were analyzed and the diagnostic performance of ATI was evaluated. Relationships between AC values and clinical characteristics were assessed by Pearson′s correlation analysis.Results:The AC values for normal liver, mild, moderate and severe fatty liver were (0.56±0.05)dB·cm -1·MHz -1, (0.68±0.09)dB·cm -1·MHz -1, (0.82±0.09)dB·cm -1·MHz -1, (0.94±0.09)dB·cm -1·MHz -1, respectively. There were significant differences in AC values among different hepatic steatosis divisions( P<0.008). There was highly significant correlation between AC values and the degree of hepatic steatosis( r=0.860, P<0.01), moderate correlation between AC values and BMI( r=0.425, P<0.01), weak correlation between AC values and HDL-C( r=-0.237, P=0.029), no correlations between AC values and age, TC, TG, LDL-C ( r=0.083, 0.055, 0.133, -0.039, all P>0.05) .The areas under the receiver operating characteristics curve of ATI for mild fatty liver and above, moderate fatty liver and above, severe fatty liver and above were 0.958, 0.962, 0.918; the sensitivity were 90.1%, 95.8%, 94.9%, the specificity were 96.1%, 87.1%, 73.9%, and the cut-off values were 0.666 dB·cm -1·MHz -1, 0.719 dB·cm -1·MHz -1, 0.803 dB·cm -1·MHz -1, respectively. Conclusions:ATI is a reliable and convenient method for evaluating the degree of hepatic steatosis in MAFLD.

4.
Chinese Journal of Ultrasonography ; (12): 48-53, 2021.
Article in Chinese | WPRIM | ID: wpr-884284

ABSTRACT

Objective:To investigate the contrast-enhanced ultrasound (CEUS) features of inflammatory hepatocellular adenoma (I-HCA).Methods:The contrast-enhanced ultrasound features I-HCA of 28 cases from April 2009 to November 2019 in Zhongshan Hospital, Fudan University were retrospectively analyzed, including arterial phase enhancement pattern, the homogeneity of enhancement, subcapsular enhancement, and the internal perfusion defect. All I-HCA lesions were divided into >5 cm group( n=9) and ≤5 cm group( n=19), the CEUS features between the two groups were compared. Results:All I-HCA lesions were hyper-enhanced in the arterial phase, among which 39.3% (11/28) showed diffuse filling, 39.3%(11/28) showed centripetal filling, and 21.4%(6/28) showed centrifugal filling pattern. Twenty-five percent (7/28) of I-HCAs showed heterogeneous enhancement, 10.7% (3/28) revealed unenhanced areas within the lesions. Subcapsular vessels were observed in 67.7 (21/31) of I-HCA lesions. Heterogeneous enhancement and unenhanced areas were more frequently detected in lesions >5 cm ( P=0.020, 0.026, respectively), while there was no difference in the enhancement pattern and subcapsular vessels between the two groups ( P>0.05). Inportal venous phase, 42.9%(12/28) of I-HCAs showed hypo-enhancement, and 57.1%(16/28) of lesions showed washout in late phase. According to "hyper-enhancement in arterial phase, sustained hyper- or iso-enhancement in portal venous and late phase" by CEUS, the diagnostic accuracy of benign lesion was 42.9%(12/28). According to any of hyper-enhancement pattern in arterial phase, subcapsular vascular enhancement, and sustained hyper- or iso-enhancement in portal venous and late phase, the diagnostic accuracy of I-HCA was 71.4% (20/28). Conclusions:CEUS is valuable in the diagnosis of inflammatory hepatocellular adenoma.

5.
Chinese Journal of Ultrasonography ; (12): 684-689, 2020.
Article in Chinese | WPRIM | ID: wpr-868068

ABSTRACT

Objective:To explore the value of contrast-enhanced ultrasound(CEUS) in distinguishing of renal oncocytoma(RO) and chromophobe renal cell carcinoma(chRCC).Methods:The ultrasonic image features of 49 ROs and 72 chRCCs between October 2007 and January 2020 were retrospectively analyzed, all lesions underwent ultrasonic examination (including 19 ROs and 70 chRCCs with CEUS imaging) and were pathologically approved in our institution. The statistically significant parameters from univariate analyses were then entered for further multivariable Logistic regression. The value of each ultrasonic imaging feature in differentiating RO and chRCC was evaluated.Results:According to the univariate analyses, all imaging features on conventional ultrasound were not statistically different between RO and chRCC (all P>0.05), while the characteristics of tumor wash-in/out pattern, enhancement degree and homogeneity at peak time and pseudocapsule around tumor were significantly different (all P<0.05). After multivariable analyses, tumor wash-in and wash-out pattern were excluded for tumor differentiation ( P>0.05), and the parameters of enhancement degree or homogeneity at peak time and pseudocapsule around tumor were still significantly different between tumor types (all P<0.05, odd ratio was 8.683, 6.667 and 18.774 respectively). The overall sensitivity, specificity and accuracy of these three parameters in diagnosing RO was 68.4%, 91.4% and 86.5%, respectively. Conclusions:CEUS can provide some useful information for the differentiation of RO and chRCC.

6.
Chinese Journal of Ultrasonography ; (12): 608-612, 2020.
Article in Chinese | WPRIM | ID: wpr-868060

ABSTRACT

Objective:To investigate the value of contrast-enhanced ultrasonography (CEUS) in detecting minute renal cell carcinoma (MRCC) smaller than 15 mm (by ultrasonic measurement) and the strategy to improve its detection rate.Methods:Fifty-three pathologically confirmed MRCCs by surgery from November 2007 to October 2019 at Zhongshan Hospital of Fudan University were enrolled in this retrospectively study. All of them underwent both conventional ultrasound and CEUS examinations. The clinical and imaging data were collected and analyzed. Common features, such as tumor size, location, echogenicity, morphology, border, and blood flow signals were observed on conventional ultrasound. On CEUS, the presence of enhancement, wash in and wash out pattern, perfusion uniformity within the lesions were observed.Results:Post-operative pathology confirmed 48 clear cell carcinomas, 4 papillary carcinomas, and 1 chromophobe cell carcinoma. On conventional ultrasound, 12/53 lesions showed no protrusion out of the kidney, and 41/53 cases slightly protruded out of the kidney. There was considerable difficulty in the detection of ten lesions, which was achieved with the guidance of CT/MRI, due to their dorsal location of the kidney. On conventional ultrasound, solid, hyper-echoic, color flow signal with varying degrees were the main features of MRCC.The boundary could be well- or ill-defined, and cystic changes existed in part of cases. On CEUS, most MRCCs showed simultaneous enhancement in cortical phase, iso- to hyper-enhancement at peak, and rapid washout in parenchymal phase. The comparisons of imaging features demonstrated that the characteristics were significantly different between conventional ultrasound and CEUS with regard to boundaries, blood supply, and perfusion uniformity (χ 2=12.425, 20.247, 7.185; all P<0.01). Conclusions:CEUS can significantly improve the detection rate of MRCC, which is superior to conventional ultrasound.

7.
Chinese Journal of Ultrasonography ; (12): 1045-1049, 2019.
Article in Chinese | WPRIM | ID: wpr-800517

ABSTRACT

Objective@#To investigate the value of contrast-enhanced ultrasound(CEUS) in differential diagnosis of complex renal cysts and clear renal cell carcinoma with cystic change(CRCCC).@*Methods@#The ultrasonographic datas of 82 lesions in 82 patients with complicated renal cysts or CRCCC confirmed by pathology were analyzed. The characteristics of conventional ultrasound and CEUS were observed and evaluated. The lesions were graded according to Bosniak classification criteria.@*Results@#Pathological examination showed that 36 cases were complicated renal cysts and 46 cases were CRCCC. Routine ultrasound showed there were 9 cases (25.0%) with cystic masses and 27 cases (75.0%) with solid and cystic masses in complex renal cysts, of which 14 cases (38.9%) could detect color flow signals. In CRCCC, 2 cases (4.3%) were with cystic masses and 44 cases (95.7%) were with solid and cystic masses, of which 33 cases (75.0%) could detect color flow signals. CEUS showed that only 18 cases (50.0%) of the complex renal cysts showed enhancement of cystic wall or septum, with equal or low enhancement at the peak, 9 cases (50.0%) accompanied by decrease of renal cortex, 35 cases (97.2%) had thin and regular cystic wall, no enhancement of cystic wall in all lesions, and 33 cases (91.7%) had septal thickness less than 1 mm. Forty-five cases (97.8%) of CRCCC showed enhancement of cystic wall or septum, 40 cases (88.9%) showed equal or high enhancement at peak, 30 cases (66.7%) were faster than the decrease of renal cortex, 37 cases (80.4%) showed uneven thickness of cystic wall, 24 cases (52.2%) showed enhancement of cystic wall nodules, and 28 cases (60.9%) showed uneven thickness of septum. After CEUS, 33 cases (91.7%) of complex renal cysts were classified as grade Ⅰ and Ⅱ, while 42 cases (91.3%) of CRCCC were classified as grade Ⅲ and Ⅳ.@*Conclusions@#The CEUS manifestations of complex renal cysts are different from those of CRCCC. The application of Bosniak criteria in CEUS is helpful for the differential diagnosis of complex renal cysts and CRCCC.

8.
Chinese Journal of Ultrasonography ; (12): 1045-1049, 2019.
Article in Chinese | WPRIM | ID: wpr-824455

ABSTRACT

Objective To investigate the value of contrast-enhanced ultrasound(CEUS)in differential diagnosis of complex renal cysts and clear renal cell carcinoma with cystic change(CRCCC).Methods The ultrasonographic datas of 82 lesions in 82 patients with complicated renal cysts or CRCCC confirmed by pathology were analyzed.The characteristics of conventional ultrasound and CEUS were observed and evaluated.The lesions were graded according to Bosniak classification criteria.Results Pathological examination showed that 36 cases were complicated renal cysts and 46 cases were CRCCC. Routine ultrasound showed there were 9 cases (25.0%) with cystic masses and 27 cases (75.0%) with solid and cystic masses in complex renal cysts,of which 14 cases (38.9%) could detect color flow signals.In CRCCC,2 cases(4.3%)were with cystic masses and 44 cases(95.7%)were with solid and cystic masses, of which 33 cases(75.0%)could detect color flow signals.CEUS showed that only 18 cases(50.0%)of the complex renal cysts showed enhancement of cystic wall or septum,with equal or low enhancement at the peak,9 cases(50.0%) accompanied by decrease of renal cortex,35 cases (97.2%) had thin and regular cystic wall,no enhancement of cystic wall in all lesions,and 33 cases(91.7%)had septal thickness less than 1 mm.Forty-five cases (97.8%) of CRCCC showed enhancement of cystic wall or septum,40 cases(88.9%)showed equal or high enhancement at peak,30 cases(66.7%)were faster than the decrease of renal cortex,37 cases (80.4%) showed uneven thickness of cystic wall,24 cases (52.2%) showed enhancement of cystic wall nodules,and 28 cases (60.9%) showed uneven thickness of septum.After CEUS,33 cases(91.7%)of complex renal cysts were classified as grade Ⅰ and Ⅱ,while 42 cases(91.3%) of CRCCC were classified as grade Ⅲ and Ⅳ.Conclusions The CEUS manifestations of complex renal cysts are different from those of CRCCC.The application of Bosniak criteria in CEUS is helpful for the differential diagnosis of complex renal cysts and CRCCC.

9.
Chinese Journal of Ultrasonography ; (12): 261-266, 2019.
Article in Chinese | WPRIM | ID: wpr-745169

ABSTRACT

Objective To prepare the vascular endothelial grow th factor receptor 2 ( VEGFR2 )/Integrinαv β3 dual‐targeted contrast ultrasound agent ,and further evaluating the physical properties ,imaging characteristics and targeted ability in v itro . Methods VEGFR2 targeted microbubble ( MBV ) ,Integrinαv β3 targeted microbubble ( MBI) and VEGFR2/Integrinαv β3 dual targeted microbubble ( MBD) were prepared by attaching VEGFR2 antibody ,Integrinαv β3 antibody and both of VEGFR2/Integrinαv β3 antibody with no targeted USphere LA respectively , using biotin‐avidin linkage method . USphere LA with no antibody attached were used as non‐targeted microbubble( MBN ) . M icrobubble′s physical properties were observed , and its stability was detected by caculating bubble′s concentration at different time points . MBD′s ultrasound imaging characteristics were evaluated by comparing its grey level of ultrasound imaging with SonoVue at the time of preparation and 3 days after preparation . To detect the targeted ability of microbubble ,different types of microbubble were added into Hepa 1‐6 and C3H10 cells ,respectively . T he above procedure was repeated using the pre‐antibody blocking test in Hepa 1‐6 cell . Results MBD had a mean size of 1 256 nm .T he concentration of microbubble in the first duration of three days was declining slowly ,and its speed was accelerated after five days of preparation . T he grey level of new prepared MBD was similar to that of SonoVue in the same concentration ( P =0 .113) ,while the level was higher than that of SonoVue within 3 days after preparation( P <0 .001) . T he number of microbubble binding to Hepea1‐6 led a tendency of MBD> single targeted microbubble > MBN ( all P <0 .05 ) . T he number of C3H10 and pre‐blocked Hepa1‐6 cell attached to each group of microbubble had no statistical difference ( all P >0 .05) . In addition ,following the pre‐blocked precedure ,the number of Hepa 1‐6 cell attached to each group of microbubble had no statistical difference either ( all P > 0 .05 ) . Conclusions VEGFR2/Integrinαv β3 dual‐targeted contrast ultrasound agent is a stable microbubble and it has excellent ultrasound imaging and targeting ability in v itro .

10.
Chinese Journal of Ultrasonography ; (12): 60-65, 2019.
Article in Chinese | WPRIM | ID: wpr-745136

ABSTRACT

Objective To explore the value of contrast-enhanced ultrasound (CEUS) in improving the diagnosis ability for xanthogranulomatous cholecystitis ( XGC ) and wall-thickening gallbladder cancer ( GBC) . Methods Forth-three patients with XGCs and 31 patients with wall-thickening GBCs proved by pathology were enrolled in this study ,the features on conventional ultrasound and CEUS were recorded ,and the preliminary diagnosis before and after CEUS were given by doctors . Results Significant differences were found in continuous gallbladder inner wall and arterial blood supplement on conventional ultrasound , 58 .1% (25/43) had continuous inner wall and 34 .9% (15/43) had arterial blood flow in XGCs compared to 19 .4% (6/31) and 100% in GBCs . On CEUS ,72 .1% (31/43) demonstrated continuous gallbladder inner wall and 48 .8% (21/43) had hypoechoic nodules in the wall in XGCs compared to 16 .1% (5/31) and 19 .4% (6/31) in GBCs ,respectively ( P <0 .05) . No significant difference was found in intra-calcification , infiltration to adjacent organs ,gallbladder stones and fast-in and fast-out enhanced pattern( P >0 .05) . The area under ROC curve was improved from 0 .701 to 0 .899 after combining with CEUS ( P < 0 .05 ) . Conclusions Conventional ultrasound combining with CEUS could help acquiring more effective ultrasonic information and may improve the differential diagnosis ability of XGCs and GBCs .

11.
Chinese Journal of Ultrasonography ; (12): 604-608, 2018.
Article in Chinese | WPRIM | ID: wpr-806984

ABSTRACT

Objective@#To analyze and summarize the ultrasonographic features of fibrolamellar hepatocellular carcinoma (FLHCC).@*Methods@#The ultrasound images were retrospectively analyzed in 23 FLHCC cases which were confirmed by pathology, including the size, echogenicity, boundary and other features on gray scale ultrasound, color Doppler flow imaging and enhancement patterns on contrast-enhanced ultrasound (CEUS).@*Results@#Twenty-three patients had 23 lesions of FLHCC. The average age was (40.0±17.1) (15-77) years old and among them 3 cases had liver cirrhosis(13.0%). The maximum diameter of FLHCC lesions was 2.5-16.7 cm and the average was (7.2±4.3)cm. On gray scale ultrasound, 82.6% (19/23) lesions were hypoechoic, 78.3% (18/23) lesions showed cord-like or sheet-like hyperechoic area and 47.8% (11/23) lesions displayed strip-like echogenic attenuation in the center, with calcification in 17.4% (4/23) lesions. There were 91.3% (21/23) lesions showed peripheral and internal rich color flow signals on color Doppler flow imaging and 60.9% (14/23) with subcapsular thick blood vessels. All 8 FLHCC lesions displayed early and hyper-enhancement in the arterial phase and wash-out in the portal and delayed phases on CEUS. Internal nonenhanced scar-like area was appeared in all lesions on CEUS.@*Conclusions@#Patients with FLHCC are mostly young and few with liver cirrhosis. Ultrasonographic features are characterized by relatively large-sized mass with internal acoustic attenuation or calcification on gray scale ultrasound and hypervascularity with central scar on CEUS.

12.
Chinese Journal of Ultrasonography ; (12): 931-935, 2018.
Article in Chinese | WPRIM | ID: wpr-707747

ABSTRACT

Objective To analyze the typical contrast-enhanced ultrasound ( CEUS ) enhancement characteristics of hepatic focal nodular hyperplasia ( FNH) within 3 cm ,and to discuss the diagnostic value of CEUS in small FNH lesions . Methods Forty-eight cases of FNH were retrospectively studied . All lesions were confirmed histopathologically after surgical resection . CEUS examinations with SonoVue were performed to characterize the enhancement patterns of lesions in 5 minutes . The whole wash in and wash out enhancement procedure of lesions were recorded and analyzed . Results All FNH lesions displayed a rapid hyper-enhancement in arterial phase by CEUS ,39 lesions of which showed spring-like enhancement ;8 lesions showed spoke-like enhancement ;1 lesion showed dendritic enhancement . 6 .3% (3/48) of the lesions showed central scar ,and feeding arteries was found in 52 .1% (25/48) lesions . According to echogenicity shift of the lesions in various phases ,20 .8% (10/48) FNH showed fast-in and slow-out" ,64 .6% (31/48) showed fast-in and synchronous-out" ,and 14 .6% (7/48) showed fast-in and fast-out" . According to fast-in and synchronous-out" or fast-in and slow-out" by CEUS ,the accuracy rate of benignity reached 85 .4% (41/48) . According to any of the spring-like enhancement ,spoke-like enhancement ,central scars or feeding arteries ,the accuracy rate of diagnosis of FNH within 3 cm reached 97 .9% (47/48) ,and 81 .3%(39/48) of which were diagnosed through spring-like enhancement . Conclusions CEUS is helpful in diagnosis of FNH within 3 cm by showing various characteristic enhancement patterns ,and spring-like enhancement is the most important sign in diagnosis of FNH less than 3 cm . CEUS has high diagnostic value for FN H less than 3 cm .

13.
Chinese Journal of Ultrasonography ; (12): 855-859, 2018.
Article in Chinese | WPRIM | ID: wpr-707735

ABSTRACT

Objective To explore the characteristics of contrast-enhanced ultrasonagraphy(CEUS) of sarcomatoid hepatocellular carcinoma ( SHC ) . Methods Fifteen lesions identified pathologically from 15 patients were included in this study . Among them ,9 lesions had completely sarcomatoid change and 6 lesions had partially sarcomatoid change . Totally 8 lesions were in the small size group with maximum diameter< 50 mm and 7 lesions in the big size group with maximum diameter ≥ 50 mm . The CEUS performance was observed and analyzed . Results In the arterial phase of CEUS ,9 lesions in the group with completely sarcomatoid change showed rim hyperenhancement and 6 lesions in the group with partially sarcomatoid change showed whole hyperenhancement , the difference between the two groups was statistically significant ( P < 0 .001 ) . However ,the difference of CEUS performance between small size group and big size group was not statistically significant ( P = 0 .608 ) , all the lesions showed hypoechogenecity in portal and(or) late phase of CEUS . Conclusions The difference of performance on CEUS is not related to the size of SHC ,but to the degree of sarcomatoid change within the tumor . SHC with completely sarcomatoid change shows rim hyperenhancement and SHC with partially sarcomatoid change shows entire hyperenhancement in arterial phase on CEUS .

14.
Chinese Journal of Ultrasonography ; (12): 805-810, 2018.
Article in Chinese | WPRIM | ID: wpr-707727

ABSTRACT

Objective To compare the ultrasound differences between gouty arthritis with chronic kidney disease( GCKD) and simple gouty arthritis( GA) ,and evaluate the correlation between the number of tophi and the degree of renal impairment . Methods Twenty-two patients with GCKD and 22 patients only with GA were examined by high frequency and color Doppler ultrasound . The differences between the tophus , intra-tendinous aggregate , double contour sign , hyperechoic spots in synovium , synovium hyperplasia ,effusion and erosion of the knee ,ankle and first metatarsophalangeal joint ( M TP 1 ) were examined . The correlation between the degree of renal impairment and the number of tophi was analyzed . Results The prevalence of tophi in GCKD group were significant serious compared with simple GA group ( Z = - 3 .915 ,P < 0 .001) . The articulations involved tophi in GCKD group were more than those in simple GA group( χ2 = 20 .283 , P < 0 .001) . And the tophi in GCKD group were more likely to involve multiple articulations while simple GA group frequently manifested none or single articulation involved( χ2 = 13 .165 , P = 0 .001 ) . The tophus in GCKD group was more frequently involved tendon than that in simple GA group ( χ2 = 6 .783 , P = 0 .009) ,but the number of aggregates in tendon showed no significant difference between the two groups ( Z = - 1 .499 , P = 0 .134) . The double contour sign was more frequent in GCKD group than that in simple GA group( χ2 = 7 .511 , P = 0 .006) ,there was no difference of hyperechoic spots in synovium ,synovium hyperplasia ,effusion and erosion between the two groups . The number of tophi was correlated with estimated glomerular filtration rate ( eGFR) ,serum creatinine( SCr) and blood urea nitrogen ( BUN) ( rs = - 0 .595 ,0 .511 ,0 .583 ;all P < 0 .001) ,respectively .Conclusions GCKD is more likely to manifest multiple tophi ,multiple tophus-involved articulations ,intra-tendinous tophi and double contour sign .The number of tophi is correlated with the degree of renal impairment .

15.
Chinese Journal of Ultrasonography ; (12): 323-327, 2018.
Article in Chinese | WPRIM | ID: wpr-707676

ABSTRACT

Objective To compare the efficiencies of handheld ultrasound ,automated breast volume scanner ( ABVS) and breast specific gamma imaging (BSGI) in the diagnosis of breast cancer . Methods A retrospective review was performed in 200 women ( 210 breast lesions) underwent handheld ultrasound , ABVS and BSGI before surgery . The results were verified with histological examination . Results There was no obvious difference among the three methods in the sensitivity for the diagnosis of breast cancer( P >0 .05) . There was no difference of specificity between handheld ultrasound and ABVS ,BSGI( P = 0 .393 , 0 .139) . Compared with BSGI ,ABVS was an imaging modality with highest specificity for the diagnosis of breast cancer( P = 0 .021) ,and there was no difference between handheld ultrasound and ABVS ,BSGI ( P =0 .07 ,0 .29) . The areas under the ROC curve of handheld ultrasound ,ABVS and BSGI were 0 .855 ,0 .894 and 0 .818 ,respectively . The difference was obvious between ABVS and BSGI ( P = 0 .02) . Conclusions The diagnostic efficacy of ABVS in diagnosis of breast malignant lesions is similar to that of handheld ultrasound . BSGI has certain clinical value in the diagnosis of breast cancer ,and it is an effective supplement for breast cancer ultrasound examination .

16.
Chinese Journal of Ultrasonography ; (12): 211-214, 2018.
Article in Chinese | WPRIM | ID: wpr-707656

ABSTRACT

Objective To evaluate the imaging features of hepatic epithelioid angiomyolipoma (EAML) on contrast-enhanced ultrasound (CEUS). Methods The imaging features of pathologically proved hepatic EAML lesions in 17 patients who had undergone baseline ultrasound and CEUS examinations were evaluated retrospectively. Results All of the cases were single lesion.70.6% (12/17) of the lesions were hypoechoic on ultrasound and 82.4% (14/17) of the lesions were heterogeneous.Flow signals were detected in 88.2% (15/17) of the lesions and 82.4% (14/17) of the lesions showed ringlike or arc arterials peripherally on color Doppler flow imaging (CDFI).The value of RI was 0.38-0.56.On CEUS,all lesions exhibited remarkable hyperenhancement in the arterial phase. 29.4% (5/17) of the lesions showed branched enhancement,70.6% (12/17) of the lesions showed diffusely entire enhancement.Strong ring-like enhancement peripherally was detected in 29.4% (5/17) of the lesions.88.2% (15/17) of the lesions were detected homogeneously enhancement during the peak period on CEUS. Washout of contrast agent and hypoechogenicity to surrounding liver tissue during portal or late phase were observed in 41.2% (7/17) and 64.7% (11/17) of the cases retrospectively.Conclusions The combination of real-time CEUS and baseline US can improve the correct diagnosis of hepatic EAML.

17.
Chinese Journal of Ultrasonography ; (12): 687-692, 2017.
Article in Chinese | WPRIM | ID: wpr-666993

ABSTRACT

Objective To evaluate the effectiveness of automated breast volume scanner(ABVS) and magnetic resonance imaging(MRI) in the detection and diagnosis of breast cancer and to assess the value of these modalities as well as the joint use of the two.Methods In this study,a total of 50 breast lesions in 37 patients proved by surgery and pathology were included.Before operation,all patients were underwent both ABVS and dynamic contrast-enhanced (DCE-MRI) examinations,and classified into groups according to BI-RADS classification.Then the effectiveness of the two examinations were contrasted,the image features on the two techniques were analyzed,and their differential diagnosis in benign and malignant breast lesions were compared.Results The sensitivity,specificity,accuracy,positive predictive value (PPV) and negative predictive value(NPV) of ABVS and MRI for the diagnosis of breast cancer were 91.67% and 95.83%,88.46% and 80.77%,90.00% and 88.00%,88.00% and 82.14%,92.00% and 95.45%,respectively,and there was no statistical difference between ABVS and MRI(P >0.05);The sensitivity and specificity of the combination of the two were 99.65% and 97.78%,respectively.The difference of the ABVS coronal features and MRI dynamic enhancement curve types between malignant breast lesions and the benign were statistically significant (P < 0.05).Conclusions Both ABVS and MRI are effective to diagnose breast cancer well,while the combination of the two can improve the diagnosis more accurately.

18.
Chinese Journal of Rheumatology ; (12): 748-753, 2017.
Article in Chinese | WPRIM | ID: wpr-663644

ABSTRACT

Objective To observe the morphological changes of carotid artery wall by ultrasonography in patients with Takayasu arteritis,and to evaluate the diagnostic value of contrast-enhanced ultrasonography for active Takayasu arteritis.Methods High-frequency ultrasound technique was used to analyze the morphological changes of the carotid artery in 40 patients.NIH score was used as the gold standard and the complete clinical data and acute phase reactors were recorded.T test,Chi-square test,sensitivity and specificity were calculated for statistical analysis.Results The thickness of carotid artery wall in active group was much more thickened than the non-active group [(2.2±0.6) mm vs (1.8±0.5) mm,t=-2.142,P<0.05].The CDD [(0.89±0.06) in active group vs (0.95±0.03) in non-active group,t=3.683,P<0.01] and RDD [(0.17±0.06 in active group vs (0.09±0.05) in non-active group,t=-4.020,P<0.01] were significantly different between the two groups.The distribution of neovascularization in the carotid artery wall of the active group was more diffuse in the central part of the wall.The sensitivity and specificity of contrast-enhanced ultrasonography to diagnose the active of Takayasu arteritis were 72.7% and 87.5% respectively,and the positive predictive value and the negative predictive value were 80.0% and 82.4% respectively.Conclusion Contrast-enhanced ultrasonography can be used as an effective way to assess the disease activity of TA patients.

19.
Chinese Journal of Ultrasonography ; (12): 1069-1073, 2017.
Article in Chinese | WPRIM | ID: wpr-707613

ABSTRACT

Objective To explore the image performance of mucinous breast carcinoma( MBC) on automated breast volume scanner ( ABVS ) and its pathologic features ,for the purpose of improving the recognition of this disease on ABVS ,as well as diagnostic ability . Methods Retrospectively analyzed the sonogram and pathological data of 17 patients with 18 MBC lesions that included 9 PMBC ( pure mucinous breast carcinoma) and 9 MMBC( mixed mucinous breast carcinoma) ,all patients were examined by ABVS before operation and confirmed by pathology . Results Luminal A was the main molecular subtype of MBC ,as well as rarely lymph node metastases;The image of the MBC on ABVS mainly showed a round like or irregular mass ,isoechoic or slightly lower with posterior acoustic enhancement ,and clearly edge with microlobulated or angular ;While on the coronal plane ,it might presented unsmoothed contour ,retraction phenomenon and expansive growth pattern like a spherical nodular;The image characteristics of the PMBC and MMBC lesions on ABVS had no statistical difference( P > 0 .05) ,but the PMBC often performed isoechoic mass with clearly marge ,in contrast , the MMBC usually performed hypoechoic mass with indistinct and angular edge ,and the malignant image features on the coronal plane . Conclusions The three vertical sections of ABVS are beneficial to observe the morphological features of MBC completely ,which can help to identify it from the benign lesions ,reduce misdiagnosis ,and provide some guidance for MBC surgical treatment in the early stage .

20.
Chinese Journal of Ultrasonography ; (12): 457-460, 2016.
Article in Chinese | WPRIM | ID: wpr-496032
SELECTION OF CITATIONS
SEARCH DETAIL